Which location is not required to be GFCI protected?
GFCI protection is not required for receptacles that are not readily accessible, such as a ceiling-mounted receptacle for a garage door opener. Nor are they required for a receptacle on a dedicated branch circuit located and identified for a cord-and-plug-connected appliance, such as a refrigerator or freezer.
Does a detached garage need power?
The International Residential Code, the most widely adopted building code in the U.S., does not require that detached garages be provided with electricity.
What are the requirements for general purpose receptacles?
Receptacles must be installed so that no point measured horizontally along the floor line in any wall space is more than 6 feet or 1.8 meters from an outlet in that space. Following the floor line from a doorway, fireplace or similar opening, the maximum distance to a receptacle is 6 feet (1.8 meters).
What is the minimum number of receptacles required in a 3 car garage?
At least one receptacle outlet shall be installed for each car space. 2017 Code Language: 210.52(G)(1) Garages. In each attached garage and in each detached garage with electric power, at least one receptacle outlet shall be installed in each vehicle bay and not more than 1.7 m (5 ½ ft) above the floor.
Do garage lights need to be GFCI protected?
NEC 210.8. 2 requires all outlets in a garage to be GFCI protected so if your lights are connected by an outlet they need GFCI protection if they are hard wired they do not require GFCI protection.
How much does an electrician charge to power a shed?
Powering a shed can be quite costly, especially if it is done by a licensed electrician. However, if you take on the task, it is important you look into how much it costs to run electricity to a shed. Usually, it is anywhere between $100-$600.
Can lights and outlets be on the same circuit?
Yes, you can. The average home uses an indoor distribution board that houses the breakers of the majority of circuits in the home. A circuit controlled by a 15A circuit breaker (which a lot of contractors use for general lighting) can also accommodate outlets.
How far off the floor should electrical outlets be?
Standard Height for Outlet Boxes The standard height for wall outlet boxes is about 12 inches from the top of the floor covering to the bottom of the receptacle box (or 16 inches to the top of the box).
How far apart can outlets be?
The maximum spacing between receptacles, according to the National Electric Code (NEC), has been set at 12-feet since 1956–with no point along a wall being more than 6-feet from a receptacle. The logic behind that number is that an appliance with a standard length cord could then be plugged-in anywhere along the wall.
Should a garage door opener be on its own circuit?
No, a garage door opener is not required to be on a separate, dedicated circuit. But, the ceiling receptacle outlet that it’s plugged into must be GFCI-protected.